Trigger 44 Description
Sequence: C34, C35
Trigger 44 ( WBR cyclic turn-off)
This trigger is designed to terminate Wideband Receiver data acquisition, which was
nominally started by one of the WBR cyclic triggers (42, 46, or 48). Data acquisition continues
for all other receivers, dust detector is resumed, and the sounder is re-enabled. If the
sounder was not running prior to the WBR cyclic, then this re-enabling has no effect.
In addition, the MFR is switched back to the EX antenna.
Receiver |
Frequency Range |
Sensors |
Time between Snapshots |
MFR |
25 - 12 KHz |
EX, BZ |
32 seconds |