Trigger 82 Description

Sequence: All
Trigger 82 (SED and Titan Lightning Mode)
This trigger steps through three HFR modes to check out possible future observations
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,BX               16.000 Seconds
MFR       25Hz-12KHz       EX,BZ               32.000 Seconds
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ       5.7 Minutes        2048
DUST      LBAND            LP                  5-10 Seconds        1024

HFR New SED Trigger

          Correlations Channels    Integ.           Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC   1E    y     n       16    n   1000  1              3.6-319KHz
HF1   2E    y     y        1    y     20  1   30     125 0.300-4.050MHz
HF2   1E    n     n        1    n     20  1   30     400 4.025-16.025MHz

Bands ABC require 2.110 sec to complete, H1 requires 1.518 sec, and
H2 requires 0.609 sec for a total of 4.237 sec per sweep.  The hfr
cycle time is 4.500 seconds.


HFR Titan Lightning

          Correlations Channels    Integ.           Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC   2E    y     y       32    y    250  1              3.6-319KHz
HF1   2E    n     y        2    n     80  1   60      25 0.100-1.600MHz
HF2   1E    n     n        1    n     20  1   72     200 1.825-16.225MHz

Bands ABC require 1.660 sec to complete, H1 requires 5.048 sec, and
H2 requires 1.461 sec for a total of 8.169 sec per sweep.  The hfr
cycle time is 8.375 seconds.



SED Source Location

          Correlations Channels    Integ.           Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
AB    2E    y     y       32    n    500  1              3.6-71KHz
HF1   2E    y     y        1    y     20  1   20     100 0.100-2.100MHz
HF2   1E    n     n        1    n     40  1   30     500 1.525-16.525MHz

Bands ABC require 1.040 sec to complete, H1 requires 1.014 sec, and
H2 requires 1.056 sec for a total of 3.111 sec per sweep.  The hfr
cycle time is 3.375 seconds.

This trigger steps through the above modes as shown below:

Duration    Step
10 Minutes  'New' SED Trigger
10 Minutes  Titan Lightning
indefinite  SED Source Location