Trigger 56 Description
Sequence: All
Trigger 56 (STV LFR Noise Check)
This trigger is based on a mode used in a series of tests that were
performed before launch, and is designed to test the noise detected by
the LFR receiver.
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,EW,BX,BZ 16.000 Seconds
MFR 25Hz-12KHz EX,EW,BX,BZ 32.000 Seconds
WFR 1Hz-40Hz EX 32.000 Seconds 512
WFR 1Hz-40Hz EW 16.000 Seconds 512
WFR 1Hz-40Hz BX 16.000 Seconds 512
WFR 1Hz-40Hz BZ 16.000 Seconds 512
The trigger steps the LFR through the following antenna choices (the MFR is also
switched to the same antenna. The data is dual routed through the LFR and the WFR.
128 seconds EX
128 seconds EW
128 seconds BX
128 seconds BZ