Trigger 2C Description
Sequence: All
Trigger 2C mode
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,BX 64.000 Seconds
MFR 25Hz-12KHz EX,BZ 32.000 Seconds
HFR 3.6KHz-16MHz EX,EW 32.000 Seconds
9 hfr packets 2003-265T00:01:25.906 2003-265T00:05:41.904
23 17 2D FB 80 03 13 0F 05 1F 01 01 01 01 DD DC DC 0D 12 04 29 47 04 3F AA
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 16 n 1000 1 3.6-319KHz
HF1 2E y y 1 n 160 1 18 100 0.325-2.125MHz
HF2 2E y y 1 n 80 1 71 200 2.075-16.275MHz
Bands ABC require 3.160 sec to complete, H1 requires 3.165 sec, and
H2 requires 6.356 sec for a total of 12.680 sec per sweep. The hfr
cycle time is 32.000 seconds.