Trigger 9C Description

Sequence: All
Trigger 9C: Toggle 10/80 kHz WBR


During the innermost SOI intervals, except during the burn, the A8 mode is used as the background mode. In addition, WBR data is acquired continuously, toggling between the 10-KHz and 80KHz bands every minute. A snapshot is taken every 1/8 second, consisting of 1437 uncompressed data bytes. The reason this is done is to target a 100 kbps data rate. The reason the data is not compressed is because compressing the 80-KHz data results in interruptions in the WFR and WBR data acquisitions, since they can not both be done at the same time unless the data is left uncompressed.

Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size 
--------  ---------------  ----------------  ----------------  -------------
MFR       25Hz-12KHz       EW,BZ               32.000 Seconds          
LPden     N/A              Langmuir Probe      48.000 Seconds          
LPswp     N/A              Langmuir Probe      48.000 Seconds          
HFR       3.6KHz-16MHz     EX,EW               16.000 Seconds          
WFR       1Hz-40Hz         EX,EW,BX,BY,BZ      48.000 Seconds      2048
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ      48.000 Seconds      2048
WBR       100Hz-10KHz      EX                   0.125 Seconds      1437
WBR       1KHz-80KHz       EX                   0.125 Seconds      1437


          Correlations Channels    Integ.           Size Frequency     
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop  
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------  
ABC   2E    y     y       16    n   1000  1              3.6-319KHz       
HF1   2E    y     y        2    n     20  1     60    25 0.325-1.825MHz   
HF2   1E    n     n        1    n     10  1     72   200 1.825-16.225MHz  

Bands ABC require 3.160 sec to complete, H1 requires 1.573 sec, and 
H2 requires 0.886 sec for a total of 5.619 sec per sweep.  The hfr 
cycle time is 16.000 seconds.