Trigger 70 Description
Sequence: All
Trigger 70 mode
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,BX 32.000 Seconds
LFR 1Hz-25Hz EX,BX 32.000 Seconds
MFR 25Hz-12KHz EX,EW,BZ 32.000 Seconds
HFR 3.6KHz-16MHz EX,EW 50.625 Seconds
WFR 50Hz-2.5KHz EX,EW,BX 0.000 Seconds 512
WFR 50Hz-2.5KHz EX,EW,BX,BY,BZ 25.000 Seconds 512
WFR 1Hz-40Hz EX,EW,BX 32.000 Seconds 512
WFR 50Hz-2.5KHz EX,EW,BX,BY,BZ 25.000 Seconds 512
WBR 100Hz-10KHz EX 4.000 Seconds 2048
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y n 32 n 1000 1 3.6-319KHz
HF1 2E y n 8 n 160 1 162 25 0.100-4.150MHz
HF2 2E y n 8 n 80 1 241 50 4.125-16.175MHz
Bands ABC require 2.945 sec to complete, H1 requires 26.457 sec, and
H2 requires 20.365 sec for a total of 49.767 sec per sweep. The hfr
cycle time is 50.625 seconds.