Trigger 1E Description
Sequence: All
Trigger 1E mode
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,BX 32.000 Seconds
MFR 25Hz-12KHz EX,BZ 32.000 Seconds
LPswp N/A Langmuir Probe 0.000 Seconds
LPden N/A Langmuir Probe 0.000 Seconds
HFR 3.6KHz-16MHz EX,EW 10.375 Seconds
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 16 n 1000 1 3.6-319KHz
HF1 2E y y 2 n 80 1 60 25 0.325-1.825MHz
HF2 1E n n 1 n 20 1 72 200 1.825-16.225MHz
Bands ABC require 3.160 sec to complete, H1 requires 5.473 sec, and
H2 requires 1.461 sec for a total of 10.094 sec per sweep. The hfr
cycle time is 10.375 seconds.