Trigger 50 Description
Sequence: All
Trigger 50 (STV MFR Noise Check)
This trigger is based on a mode used in a series of tests that were
performed before launch, and is designed to test the noise detected by
the MFR receiver.
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
MFR 25Hz-12KHz EX,EW,BX,BZ 32.000 Seconds
The antenna the MFR is attatched to is switched as shown below
128 seconds Fixed Ex
128 seconds Fixed EW
128 seconds Fixed Bx
128 seconds Fixed Bz
256 seconds Toggle Bx/Bz
256 seconds Toggle Ex/Bx
256 seconds Toggle Ex/Bz