Trigger 70 Description

Sequence: All
Trigger 70 (MAG Turn-on Test Mode)
This trigger is a 'listen' mode to observe the turn on of other instrument. The WFR/LFR data is dual routed.
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,BX               16.000 Seconds
MFR       25Hz-12KHz       EX,BZ               32.000 Seconds
WFR       1Hz-40Hz         EX,EW,BX            16.000 Seconds       512
WFR       50Hz-2.5KHz      EX,EW,BX,BY,BZ      25.000 Seconds       512
WBR       100Hz-10KHz      EX                   4.000 Seconds      2048



          Correlations Channels    Integ.           Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC   2E    y     n       32    n   1000  1              3.6-319KHz
HF1   2E    y     n        8    n    160  1   162     25 0.100-4.150MHz
HF2   2E    y     n        8    n     80  1   241     50 4.125-16.175MHz

Bands ABC require 2.945 sec to complete, H1 requires 26.457 sec, and
H2 requires 20.365 sec for a total of 49.767 sec per sweep.  The hfr
cycle time is 51.000 seconds.