Trigger A4 Description
Sequence: S05,...
Trigger A4 ( HRSED 182 kbps Hirate Mode )
This mode is designed to provide a hirate mode for analyzing fine structure of SED's,
while also providing a low temporal resolution spectrum at the spectral resolution.
This is accomplished by running the WBR in the "down-convert" mode, using the 25-KHz
wide signal provided by the HFR, which is simultaneously running in millisecond at
the frequency provided to the WBR. This mode of operation is paused every 64 seconds
for 8 seconds, in order to perform a normal analysis sweep, nominally in SEDDF mode.
At this time, the LFDR is also sampled. These provide the low temporal resolution spectrum.
At each 64-second interval the millisecond mode frequency is toggled between each of two
selections: 2 MHz and 10 MHz. These frequencies could be tweaked with additional commands.
WFR data acquisition and Dust detection are not done. Langmuir Probe sweeps are performed
every 640 seconds. A Sounder measurement is scheduled every 10 minutes.
It is assumed that prior to this trigger, either trigger A0 (SEDDF) or trigger
8E (Night-Time Survey) was in effect.
Receiver |
Frequency Range |
Sensors |
Time between Snapshots |
Snapshot Length |
LFR |
1 - 25 Hz |
EX, BX |
126 seconds |
MFDR |
70Hz - 1.7KHz |
EX, BX |
126 seconds |
MFR |
25 - 12 KHz |
EX, BZ |
32 seconds |
HFR |
3.6 KHz - 16 MHz |
EX, EW |
64 seconds |
HFR |
2 MHz or 10 MHz band |
EX |
2.5 seconds |
2048 |
WBR |
2 MHz or 10 MHz band |
EX |
0.125 second |
4096 |
The HFR is in a modified "Composite Survey" mode, which now includes
both auto- and cross-correlations for H1, and differs from standard
Survey mode in that its integration constants for H1 and H2 are shorter.
This mode is defined by:
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 32 n 500 1 3.6-319KHz
HF1 2E y y 2 n 40 1 60 25 0.325-1.825MHz
HF2 1E n n 1 n 40 1 72 200 1.825-16.225MHz
Bands ABC require 1.560 sec to complete, H1 requires 2.852 sec, and
H2 requires 2.534 sec for a total of 6.946 sec per sweep. The hfr
cycle time is 64 seconds.