Trigger 78 Description

Sequence: C14 (Venus-2) (ESB)
Trigger 78 (Venus-2 Observation Continuation)

This mode allows the instrument to re-enter the mode initiated by Trigger 74 without the
setup time of Trigger 74. This trigger must only be sent after Trigger 74, and has the same
instrument settings as Trigger 74. The HFR is allowed to free run, and the HFR data is NOT compressed.
LFR, MFR, and WFR data are also collected, resulting in the entire RPWS frequency range
(1 Hz - 16 MHz) to be covered.


Receiver Frequency Range Sensors Time between Snapshots
LFR 1 - 25 Hz EX, BX 16 seconds
MFR 25 - 12 KHz EX, BZ 32 seconds
WFR .1 - 2.5 KHz EX, EW, BX, BY, BZ 342 seconds
HFR 3.6 KHz - 16 MHz EX 32 seconds


The HFR is in a special Venus-2 Lightning Scan mode.

This mode is defined by:

          Correlations     Channels        Integ.                Size Frequency
Band Ant. Auto-  Cross-    per Band   df   Period    Rep   Steps kHz  Start - Stop
---- ---- -----  ------    --------   --   ------    ---   ----- ---- ------------
ABC  1E    y         n        32       n    125       1                3.6 kHz-319 kHz
H1   1E    n         n         1       n     20       1     12    350  125 kHz-3.975 MHz
H2   1E    n         n         1       n     10       1      8   1500  5.47 5MHz-15.975 MHz

The HFR is free-running, resulting in:
Bands ABC require 0.242 sec to complete, H1 requires 0.242 sec, and H2 requires 0.098 sec
for a total of 2.33 sec per sweep. However, the HFR actually only performs one complete
sweep every 2.5 seconds.