Trigger 3E Description
Sequence: C19,...
Trigger 3E ( Fast 2.5KHz WFR )
This trigger is designed to provide 2.5 KHz WFR data with a
high temporal resolution. Data acquisition continues for the LFR,
MFR, and HFR.
Receiver |
Frequency Range |
Sensor |
Cycle Time |
Snapshot Size |
LFR |
1 - 25 Hz |
EX, BX |
32 seconds |
MFR |
25 Hz - 12 KHz |
EX, BZ |
32 seconds |
HFR |
3.6 KHz - 16 MHz |
EX, EW |
7.375 seconds |
WFR |
.05 - 2.5 KHz |
EX, EW, BX, BY, BZ |
20 seconds |
2048 |
The HFR is in CMS mode (Composite Mode Survey). No direction-finding is done.
This mode is defined by:
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 16 n 1000 1 3.6-319 kHz
H1 2E n y 2 n 80 1 30 50 325k-1.8MHz
H2 1E n n 1 n 20 1 72 200 1.8M-16MHz
Bands ABC require 3.16 sec to complete, H1 requires 2.52 sec, and H2 requires 1.46 sec
for a total of 7.25 sec per sweep. Data collection and output limits the snapshot
time to 7.375 seconds.