Trigger 44 Description
Sequence: C18,...
Trigger 44 ( 1 MHz HF-WBR )
This trigger is designed to produce High-Frequency (HF) Wideband Receiver data at 1 MHz.
Data acquisition continues only for the MFR. The HFR is placed in millisecond mode at
1 MHz during this trigger's operation.
This trigger turns on compression of the WBR data, and forces the snapshot length
to 4096 samples. The HFR millisecond mode sample set size is set to 256, because of
the unique telemetry mode (SAF142) which this mode is designed for. Telemetry is
picked up once every 1/4 second in this mode.
Receiver |
Frequency Range |
Sensor |
Time between Snapshots |
Samples per Snapshot |
MFR |
25 Hz - 12 KHz |
EX, BZ |
32 seconds |
HFR |
1.025 MHz |
EX |
1.25 seconds |
256 |
WBR |
1.01-1.04 MHz |
EX |
1.25 second |
4096 |