Trigger 22 Description
Sequency: All
Trigger 22 (Basic Survey Mode)
This mode provides the standard basic survey mode with the Sounder and Langmuir Probe
data added.
Receiver Frequency Range Sensor Cycle Time Snapshot Size
-------- --------------- ---------------- ---------------- -------------
LFR 1Hz-25Hz EX,BX 16.000 Seconds
MFR 25Hz-12KHz EX,BZ 32.000 Seconds
WFR 50Hz-2.5KHz EX,EW,BX,BY,BZ 5.7 Minutes 2048
LP N/A Langmuir Probe 10 Minutes 37 (density)
Sounder 3.6-115KHz EX,EW 10 Minutes
DUST LBAND EW 5-10 seconds 512
Correlations Channels Integ. Size Frequency
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz Start - Stop
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------
ABC 2E y y 16 n 1000 1 3.6-319KHz
HF1 2E n y 2 n 80 1 60 25 0.325-1.825MHz
HF2 1E n n 1 n 20 1 72 200 1.825-16.225MHz
Bands ABC require 3.160 sec to complete, H1 requires 5.048 sec, and
H2 requires 1.461 sec for a total of 9.669 sec per sweep. The hfr
cycle time is 9.875 seconds.
Every 600 seconds the HFR normal analyses are interrupted by a Sounder analysis.
This Sounder analysis is defined by:
sounder mode: EX AAA
1st sounder freq: 0
last sounder freq: 89
T1 delay: 5 msec
T2 delay: 5 msec
T3 delay: 15 msec
passive spectra: 2
active spectra: 2
# of cycles: 1
sounder output A: 3 autos
sounder output B: 3 AGCs