Trigger 72 Description

Sequence: All
Trigger 72 mode
Receiver  Frequency Range       Sensor          Cycle Time     Snapshot Size 
--------  ---------------  ----------------  ----------------  -------------
LFR       1Hz-25Hz         EX,BX               32.000 Seconds          
MFR       25Hz-12KHz       BZ                  32.000 Seconds          
LPswp     N/A              Langmuir Probe      16.000 Seconds          
LPden     N/A              Langmuir Probe      16.000 Seconds          
HFR       3.6KHz-16MHz     EX,EW               56.000 Seconds          
Cal       3.6KHz-16MHz                          0.000 Seconds          
WFR       1Hz-40Hz         EX,EW,BX,BY,BZ      25.000 Seconds       512
WBR       100Hz-10KHz      BX                   8.000 Seconds      2048
WBR       1KHz-80KHz       HF                   8.000 Seconds      1712


          Correlations Channels    Integ.           Size Frequency     
Band Ant. Auto- Cross- per Band df Period Rep Steps kHz  Start - Stop  
---- ---- ----- ------ -------- -- ------ --- ----- ---- ------------  
ABC   2E    y     y       32    n   1000  1              3.6-319KHz       
HF1   2E    y     y        4    n    160  1     70    25 0.250-2.000MHz   
HF2   2E    y     y        1    n     80  1     70   200 2.025-16.025MHz  

Bands ABC require 3.120 sec to complete, H1 requires 12.301 sec, and 
H2 requires 6.266 sec for a total of 21.687 sec per sweep.  The hfr 
cycle time is 56.000 seconds.