Trigger A4 Description

Sequence: C34, C35
Trigger A4 ( HRSED 182 kbps Hirate Mode )

This mode is designed to provide a hirate mode for analyzing fine structure of SED's, while also providing a low temporal resolution spectrum at the spectral resolution. This is accomplished by running the WBR in the "down-convert" mode, using the 25-KHz wide signal provided by the HFR, which is simultaneously running in millisecond at the frequency provided to the WBR. This mode of operation is paused every 64 seconds for 8 seconds, in order to perform a normal analysis sweep, nominally in SEDDF mode. At this time, the LFDR is also sampled. These provide the low temporal resolution spectrum. At each 64-second interval the millisecond mode frequency is toggled between each of two selections: 2 MHz and 10 MHz. These frequencies could be tweaked with additional commands. WFR data acquisition and Dust detection are not done. Langmuir Probe sweeps are performed every 640 seconds. A Sounder measurement is scheduled every 10 minutes.
It is assumed that prior to this trigger, either trigger A0 (SEDDF) or trigger 8E (Night-Time Survey) was in effect.

Receiver Frequency Range Sensors Time between Snapshots Snapshot Length
LFR 1 - 25 Hz EX, BX 64 seconds
MFR 25 - 12 KHz EX, BZ 32 seconds
HFR 3.6 KHz - 16 MHz EX, EW 64 seconds
HFR 2 MHz or 10 MHz band EX 2.25 seconds 2048
WBR 2 MHz or 10 MHz band EX 0.125 second 4096
LP N/A Probe 640 seconds
Sounder 3.6 - 115 KHz EX, EW 600 seconds



The HFR is in a modified "Composite Survey" mode, which now includes both auto- and cross-correlations for H1, and differs from standard Survey mode in that its integration constants for H1 and H2 are shorter. This mode is defined by:
          Correlations     Channels        Integ.                Size Frequency
Band Ant. Auto-  Cross-    per Band   df   Period    Rep   Steps kHz  Start - Stop
---- ---- -----  ------    --------   --   ------    ---   ----- ---- ------------
ABC  2E   y         y        16       n    1000      1                3.6-319 kHz
H1   2E   y         y         2       n    20        1     60    25   325k-1.8MHz
H2   1E   n         n         1       n    10        1     72    200  1.8M-16MHz
Bands ABC require 3.16 sec to complete, H1 requires 1.57 sec, and H2 requires 0.65 sec for a total of 5.62 sec per sweep. This fits into the 8-second slot allowed for the normal analysis performed every 64 seconds. Every 600 seconds the HFR normal analyses are interrupted by a Sounder analysis. The Sounder operation has a duration of approximately 40 seconds. This Sounder analysis is defined by:
  sounder mode:   EZ AAA
  1st  sounder freq:      0
  last sounder freq:     89
  T1 delay:        10 msec
  T2 delay:        25 msec
  T3 delay:        25 msec
  passive spectra:      2
  active  spectra:      2
  # of cycles:       1
  sounder output A:      3 autos
  sounder output B:      3  AGCs